IP명 | High-performance Bio-Impedance Measurement System using a Δ-ΔΣ-based Receiver | ||
---|---|---|---|
Category | Mixed | Application | Electrical Impedance Tomography |
실설계면적 | 5㎛ X 7㎛ | 공급 전압 | 1.2V |
IP유형 | Soft IP | 동작속도 | 80kHz |
검증단계 | Silicon | 참여공정 | HM-2205 |
IP개요 | A Δ-ΔΣ-based bio-impedance measurement system is realized for wearable devices. A high dynamic range is achieved by Δ-modulation, which functions as a baseline cancellation. In addition, techniques such as chopping and dynamic element matching are used for high-precision measurement. |
||
- 레이아웃 사진 - |